Simon XT - External Siren Programming
A few hardwired siren are compatible with the Simon XT
- Interlogix / GE 13-046 Outdoor Siren
- Interlogix / GE 13-950 Outdoor Siren
- Interlogix / GE LD105 Indoor Siren
- ATW Bulldog Indoor Siren
- ATW Bloodhound Indoor Siren
1. Siren has a black and a red wire. These tie into Simon XT wiring terminals
2. Remove screw on the top of panel
3. Push 2 white tabs on top of panel, and pull front of panel forward
3. Wiring terminals are located on bottom left-hand corner of Simon XT
4. Connect black wire to HW1 terminal, connect red wire to HW1&2 terminal
5. Connect 4.7 K resistor and wires together, follow the instructions below...
A. Twist black wires together and red wires together.
B. Place B-Connector on end of twisted wires and insert resistor in both B-Connectors
C. Squeeze B-Connector with pliers
6. Some changes in Simon XT programming are now required
7. Press or
until SYSTEM PROGRAMMING then press
8. Enter Installer Code 4321 (If Monitronics enter 1960, 6529 or 2545)
9. Press or
until SENSORS then press
10. Press or
until HW SIREN SUP then press
then press 1 to enable then
11. Press STATUS to exit then press or
until SYSTEM OPTIONS then press
12. Press or
until HW SIREN SUP then press
, enter 1 then press
13. Press STATUS several times to exit programming