How to Program the 2GIG-CO3-345 to the GC2 Panel

Step-by-Step Instructions:

1. Press the bottom right logo, enter the default installer code 1561 or 1171, then press System Configuration.

000.1a Programming - Enter Program 01 278x158

000.1b User Menu - Disarm 05 278x158

000.1c Programming - Enter Program 03 278x158


2. Starting at Q1 RF Sensor programming, enter the sensor or press Go To and enter the location.

000.2a Programming - Enter Program 04 278x158

000.2b 2GIG Q2 Wired Programming 1 Select 280x159

000.2c Programming - Enter Program 05 278x158


3. Enter sensor 01 to 60, or press the arrow buttons to scroll to sensor 01 to 60. Press the down arrow for the next step.

001 2GIG Q1 RF Sensor Programming 01 Select 278x158


4. Enter 09, or press the arrow buttons to scroll to (14) 24-Hour Carbon Monoxide. Press the down arrow for the next step.

002 2GIG Q1 RF Sensor Programming 02 Type 14 Carbon Monoxide 278x158


5. Press the arrow buttons to scroll to (1026) 2GIG CO Detector, then press the down arrow to continue to the next step.

003 2GIG Q1 RF Sensor Programming 02 Equipment Code 1026 CO Detector 278x158


6. Enter the serial number from the sensor sticker, or press Shift then Learn followed by pressing the test button on the sensor or by opening the sensor cover to learn it. Press Ok.

004a 2GIG Q1 RF Sensor Programming 05 Serial Number 1 278x158004b 2GIG Q1 RF Sensor Programming 05 Serial Number 2 278x158004c 2GIG Q1 RF Sensor Programming 05 Serial Number 3 278x158


7. Press the down arrow to continue to the next step.

005 2GIG Q1 RF Sensor Programming 05 Serial Number 4 278x158


8. Enter 0 or press the arrow buttons to scroll to (0) new, then press the down arrow to continue to the next step.

006 2GIG Q1 RF Sensor Programming 06 Equipment Age 278x158


9. Enter Loop 1 or press the arrow buttons to scroll to (1) 1, then press the down arrow to continue to the next step.

007 2GIG Q1 RF Sensor Programming 07 Loop Number 278x158


10. Press Insert, then enter the 3-digit word 032 Carbon Monoxide or press the arrow buttons to scroll all words.

008a 2GIG Q1 RF Sensor Programming 09 Description 1 Blank 278x158008b 2GIG Q1 RF Sensor Programming 09 Description 2 Front 278x158


11. Press Insert then enter 3-digits for next word (up to 6 total) or press the down arrow to finish.

009 2GIG Q1 RF Sensor Programming 09 Description 3 Front Door 278x158


12. Enter 1 or press the arrow buttons to scroll to (1) enabled for central station reports. Press the down arrow to continue to the next step.

010 2GIG Q1 RF Sensor Programming 10 Reports 278x158


13. Enter 1 or press the arrow buttons to scroll to (1) enabled for sensor supervision, then press the down arrow to continue to the next step.

011 2GIG Q1 RF Sensor Programming 11 Supervision 278x158


14. Enter 00 or press the arrow buttons to scroll to (00) disabled to disable door chimes, then press the down arrow to continue to the next step.

012 2GIG Q1 RF Sensor Programming 12 Chime 278x158


15. Press Edit Next to add any additional sensors, or press End then Exit to complete.

013 2GIG Q1 RF Sensor Programming 13 Summary 1 278x158X1 Programming - Exit Program 01 278x158X2 Programming - Exit Program 02 278x158